{"product_id":"abatement-technologies-hepa-care®-hc800fd-commercial-air-purifier","title":"Abatement Technologies HEPA-CARE® HC800FD Commercial Air Purifier","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eStruggling to Maintain Cleanroom-Level Air Quality? This HEPA-CARE® Commercial Air Purifier Provides High-Capacity Filtration for Reliable Particle Control\u003c\/h2\u003e\n\u003cp\u003eAir quality isn’t just a comfort issue in clinical or controlled environments—it’s part of the job. The HEPA-CARE® HC800FD from Abatement Technologies is a commercial air purifier designed for places where air turnover, particle control, and infection prevention matter every single day. Hospitals, labs, and pharmaceutical spaces all face the same quiet challenge: keeping air clean, consistent, and dependable without rebuilding the entire HVAC system.\u003c\/p\u003e\n\u003cp\u003eAt 925 CFM, this unit delivers serious airflow with true HEPA performance. That kind of output isn’t random. It’s sized to help real facilities reach meaningful air change targets—often around 6 to 15 ACH in healthcare rooms, and sometimes much higher in clean environments. And when a portable unit can help close that gap? That’s when it starts earning its keep.\u003c\/p\u003e\n\u003cp\u003eHere’s the thing. A \u003ca href=\"https:\/\/hcairsolutions.com\/collections\/commercial-air-purifier\" title=\"commercial air purifier\" rel=\"noopener\" target=\"_blank\"\u003ecommercial air purifier\u003c\/a\u003e only works if it moves enough air to make a difference. In a patient room around 4,000 cubic feet, reaching roughly 12 air changes per hour takes about 800 CFM. So 925 CFM gives you breathing room—literally. It helps compensate for filter loading, placement losses, and the everyday realities that reduce performance over time.\u003c\/p\u003e\n\u003cp\u003eYou’ll see this type of air purification system used where risk runs higher or occupancy runs dense. Waiting areas. Treatment rooms. Temporary isolation spaces. Labs managing fine particles from sample prep. Even pharmaceutical compounding rooms where particle control supports compliance and product quality. In each case, the goal is simple: move more clean air through the space, more often.\u003c\/p\u003e\n\u003cp\u003eHEPA filtration at this scale captures microscopic particles at 99.97% efficiency down to 0.3 microns. That includes bioaerosols, fine dust, and airborne contaminants that standard ventilation doesn’t always catch fast enough. It’s not flashy—but it’s dependable. And honestly, that’s what most facilities care about.\u003c\/p\u003e\n\u003cp\u003eThere’s also a practical side people don’t talk about much. A higher-capacity commercial air purifier can cover a larger footprint with fewer units. That means less setup, fewer maintenance points, and a cleaner deployment plan overall. One device doing real work instead of three smaller ones trying to keep up.\u003c\/p\u003e\n\u003cp\u003eIn labs and pharmaceutical settings, the same airflow helps support higher ACH targets tied to cleanroom-style environments. Think dilution of airborne particles, faster recovery after a process change, and added confidence when base ventilation alone can’t keep pace.\u003c\/p\u003e\n\u003cp\u003eIt’s not meant to replace building systems outright. It works alongside them. Supplements them. Strengthens the air handling strategy already in place.\u003c\/p\u003e\n\u003cp\u003eAnd that’s really the story here. The HEPA-CARE® HC800FD isn’t about bells and whistles. It’s about reliable airflow, strong HEPA performance, and the kind of consistency that keeps controlled spaces stable—even when conditions change.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable style=\"width: 100%; height: 901.234px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 19.5938px;\"\u003e\u003cstrong\u003eNet Weight (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 19.5938px;\"\u003e83 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 78.375px;\"\u003e\u003cstrong\u003eDimensions (D x W x H) in\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 78.375px;\"\u003e21.125\" x 20.375\" x 47.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 39.1875px;\"\u003e\u003cstrong\u003eElectrical Rating (V\/HZ\/A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 39.1875px;\"\u003e120 VAC, 60 Hz, 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.75px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 58.75px;\"\u003e\n\u003cstrong\u003eAir Flow* Max\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ew\/Clean Filter (CFM)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 58.75px;\"\u003eup to 925 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Operating Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 19.5938px;\"\u003e6 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 137.141px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 137.141px;\"\u003e\u003cstrong\u003eMotor Impeller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 137.141px;\"\u003e2 EC Motorized Impellers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 58.7812px;\"\u003e\u003cstrong\u003eMotorized Impeller Speed Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 58.7812px;\"\u003e5 Touch Screen Speed Settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 117.562px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 117.562px;\"\u003e\u003cstrong\u003ePower Cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 117.562px;\"\u003e10 Ft. 14\/3 AWG SJT cord, 15 Amp\/120 Volt AC Hospital Grade Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 19.5938px;\"\u003e\u003cstrong\u003eSound Level @ 5 Feet (dBA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 19.5938px;\"\u003e37-59 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 58.7812px;\"\u003e\u003cstrong\u003eHEPA Filter Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 58.7812px;\"\u003e99.995% @ 0.3 Microns, Gel Seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 78.375px;\"\u003e\u003cstrong\u003eCabinet Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 78.375px;\"\u003ePower Coated Aluminum, Riveted and Sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 78.375px;\"\u003e\u003cstrong\u003eFirst Stage Prefilter - 1 each\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 78.375px;\"\u003eHC1802AM 2\" ASHRAE MERV 8 Pleated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 78.375px;\"\u003e\u003cstrong\u003eOptional VAPOR-LOCK Prefilter  - 1 each\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 78.375px;\"\u003eHC1802CF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.75px;\"\u003e\n\u003ctd style=\"width: 79.4224%; height: 58.75px;\"\u003e\u003cstrong\u003eHEPA Filter  - 1 each\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20.2166%; height: 58.75px;\"\u003eHC1836-H14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\n\u003cbr\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful 150–925 CFM Adjustable Airflow\u003c\/strong\u003e\u003cbr\u003eFive selectable airflow settings let you match performance to the room size and risk level. At peak output, the unit can help achieve 12+ air changes per hour in spaces up to roughly 4,000–4,625 cubic feet, supporting infection control and particle reduction where it matters most.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue H14 HEPA Filtration (99.995% @ 0.3 Microns)\u003c\/strong\u003e\u003cbr\u003eEach pharmaceutical-grade HEPA filter is individually tested and certified to capture microscopic particles, including fine dust, bioaerosols, and airborne contaminants. The silicone-gel seal and zero-bypass cabinet design help ensure that air is forced through the filter—not around it.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuickly Converts Rooms into Negative Pressure Isolation Areas\u003c\/strong\u003e\u003cbr\u003eDesigned for healthcare use, the system can help transform a standard patient room into a negative pressure space that supports CDC ventilation goals. This makes it a practical option for temporary isolation, surge capacity, or high-risk treatment areas.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Motorized Impellers Built for Continuous Operation\u003c\/strong\u003e\u003cbr\u003eEnergy-efficient blowers rated for up to 100,000 hours of maintenance-free service deliver strong, consistent airflow. That kind of durability supports 24\/7 operation in demanding clinical, lab, and pharmaceutical environments.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation for Occupied Spaces (37–59 dBA @ 5’)\u003c\/strong\u003e\u003cbr\u003eEven at higher airflow settings, sound levels remain low enough for patient rooms, treatment areas, and labs. It runs in the background without adding stress to staff or patients.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntuitive 3.25\" Touchscreen with Smart Monitoring\u003c\/strong\u003e\u003cbr\u003eThe color LCD control panel offers password protection, menu-driven navigation, and real-time status indicators. Visual alerts notify staff when filters are nearing capacity, helping prevent performance drop-off and simplifying maintenance planning.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable, Space-Saving Design for Fast Deployment\u003c\/strong\u003e\u003cbr\u003eA narrow upright profile, swivel casters, and foot brakes make it easy to move and position in tight rooms or crowded clinical settings. You can deploy it where needed most without permanent installation.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Carbon Filtration for Odors and Gas-Phase Contaminants\u003c\/strong\u003e\u003cbr\u003eAdd a VAPOR-LOCK® carbon pre-filter to help remove odors and certain airborne gases. This is especially useful in treatment areas, labs, or pharmaceutical spaces where air quality concerns go beyond particles alone.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003eManual\u003c\/p\u003e","brand":"Abatement Technologies","offers":[{"title":"Default Title","offer_id":42506214604889,"sku":"HC800FD","price":5200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/AbatementHEPA-CARE_HC800FDCommercialAirPurifierpic1.png?v=1752641811","url":"https:\/\/hcairsolutions.com\/products\/abatement-technologies-hepa-care%c2%ae-hc800fd-commercial-air-purifier","provider":"HC Air Solutions","version":"1.0","type":"link"}