{"product_id":"koldwave-21-000-btu-commercial-portable-air-conditioner-7kk21","title":"Koldwave 21,000 BTU Commercial Portable Air Conditioner (7KK21)","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eNeed Immediate Cooling Where HVAC Falls Short? This 21,000 BTU Commercial Portable Air Conditioner Stabilizes Temperatures and Restores Control Fast\u003c\/h2\u003e\n\u003cp\u003eWhen cooling needs to happen quickly—and flexibility matters—this \u003ca href=\"https:\/\/hcairsolutions.com\/collections\/commercial-portable-air-conditioner\" title=\"commercial portable air conditioner\" rel=\"noopener\" target=\"_blank\"\u003ecommercial portable air conditioner\u003c\/a\u003e becomes a practical solution, not a backup plan. The Koldwave Model 7KK21 air-cooled portable is designed for situations where permanent HVAC can’t keep up, can’t be altered, or simply isn’t available. Those situations aren’t rare, especially in facilities that run hot, run full, or can’t afford downtime.\u003c\/p\u003e\n\u003cp\u003eWith a cooling capacity of 21,000 BTU, this unit fits a very usable range. It’s capable of supporting larger rooms, shared spaces, and areas with elevated heat from people or equipment, while remaining fully portable and non-permanent. Depending on heat load and layout, it typically covers 700 to 1,000+ square feet, giving operators added cooling without committing to construction or system changes.\u003c\/p\u003e\n\u003cp\u003eThe air-cooled design keeps deployment straightforward. Unit requires power and a path to exhaust hot air—nothing more. There’s no water connection to manage and no infrastructure to install. That simplicity makes the 7KK21 easy to move, quick to set up, and well-suited for temporary needs, emergency response, or spaces where cooling demands change over time.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 450.657px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eV\/Ph\/Hz\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e230\/1\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eCooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eBTU\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e21,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eW\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e2,200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e10.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003ePlug Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003eNEMA 6-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Cord Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eAWG\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Cord Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eFt.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e10'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions W x D x H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003ein.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e21\" x 27\" x 41\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eLbs\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e187\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Cool Air Outlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eLbs\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondensate Tank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eGallons\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e4 Gal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003e\u003cspan\u003e°F\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e64-113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eSetting Temperature (Room Cool mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003e\u003cspan\u003e°F\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e64-86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eSetting Temperature (Spot Cool Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003e\u003cspan\u003e°F\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e32-86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication Area (Room Cool Mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eFt.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e538ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eRefrigerant Amount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eoz.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eIndoor Air Flow (High)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eCFM\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eIndoor Air Flow (Low)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eCFM\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e465\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eWheel Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003ein.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eHot Air Duct Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003ein.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Duck Length (Cold Air Supply)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eFt.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e30'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 65.704%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Duct (Hot Air Discharge)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.6065%; height: 19.5938px;\"\u003eFt.\u003c\/td\u003e\n\u003ctd style=\"width: 16.787%; height: 19.5938px;\"\u003e50'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch6\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli data-start=\"254\" data-end=\"517\"\u003e\n\u003cp data-start=\"256\" data-end=\"517\"\u003e\u003cstrong data-start=\"256\" data-end=\"315\"\u003e21,200 BTU of Targeted Spot Cooling for High-Heat Areas\u003c\/strong\u003e\u003cbr data-start=\"315\" data-end=\"318\"\u003eDelivers powerful, localized cooling for rooms and zones where central HVAC can’t keep up—ideal for equipment rooms, temporary spaces, or crowded work areas without overcooling the entire building.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"519\" data-end=\"758\"\u003e\n\u003cp data-start=\"521\" data-end=\"758\"\u003e\u003cstrong data-start=\"521\" data-end=\"581\"\u003eSpot-Cool and Room-Cool Modes for Real-World Flexibility\u003c\/strong\u003e\u003cbr data-start=\"581\" data-end=\"584\"\u003eSwitch between focused spot cooling and full room cooling using a dedicated thermostat, allowing the unit to adapt to changing layouts, loads, and usage throughout the day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"760\" data-end=\"991\"\u003e\n\u003cp data-start=\"762\" data-end=\"991\"\u003e\u003cstrong data-start=\"762\" data-end=\"816\"\u003eAir-Cooled Design for Fast, Hassle-Free Deployment\u003c\/strong\u003e\u003cbr data-start=\"816\" data-end=\"819\"\u003eRequires only electrical power and a way to vent hot air—no water lines or plumbing—making it easy to deploy during outages, renovations, or emergency cooling situations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"993\" data-end=\"1224\"\u003e\n\u003cp data-start=\"995\" data-end=\"1224\"\u003e\u003cstrong data-start=\"995\" data-end=\"1048\"\u003eDual Directional Nozzles with High Airflow Output\u003c\/strong\u003e\u003cbr data-start=\"1048\" data-end=\"1051\"\u003eTwo adjustable cold-air outlets deliver up to \u003cstrong data-start=\"1099\" data-end=\"1110\"\u003e560 CFM\u003c\/strong\u003e, letting operators aim cooling exactly where heat builds up, whether that’s a rack, workstation, or patient area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1226\" data-end=\"1450\"\u003e\n\u003cp data-start=\"1228\" data-end=\"1450\"\u003e\u003cstrong data-start=\"1228\" data-end=\"1284\"\u003eBuilt-In Self-Diagnostic Controls with Clear Display\u003c\/strong\u003e\u003cbr data-start=\"1284\" data-end=\"1287\"\u003eThe onboard control panel shows operating modes, set and room temperatures, and fault codes, helping staff identify issues quickly without guesswork or downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1700\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1454\" data-end=\"1496\"\u003eDesigned for Continuous Commercial Use\u003c\/strong\u003e\u003cbr data-start=\"1496\" data-end=\"1499\"\u003eFeatures a double-shaft motor powering two blowers, internal fiberglass insulation, and rust-proof ABS panels—built to handle demanding environments like hospitals, warehouses, and industrial spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1702\" data-end=\"1931\"\u003e\n\u003cp data-start=\"1704\" data-end=\"1931\"\u003e\u003cstrong data-start=\"1704\" data-end=\"1744\"\u003eMobility That Matches Changing Needs\u003c\/strong\u003e\u003cbr data-start=\"1744\" data-end=\"1747\"\u003eHeavy-duty twin-wheel casters make the unit easy to move between rooms or departments, supporting temporary cooling, seasonal demand, or shifting hot spots without installation work.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1933\" data-end=\"2206\"\u003e\n\u003cp data-start=\"1935\" data-end=\"2206\"\u003e\u003cstrong data-start=\"1935\" data-end=\"1970\"\u003eSafety and Reliability Built In\u003c\/strong\u003e\u003cbr data-start=\"1970\" data-end=\"1973\"\u003eIncludes compressor overload protection, high-pressure switch, anti-freezing thermistor, full drain tank switch, automatic restart after power loss, and an optional condensate pump with overflow protection for unattended operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003eManual\u003c\/p\u003e","brand":"Koldwave","offers":[{"title":"Default Title","offer_id":42435272441945,"sku":"7KK21","price":6179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/21_000BTUPortableAirConditionerbyKoldwave_7KK21.png?v=1749873176","url":"https:\/\/hcairsolutions.com\/products\/koldwave-21-000-btu-commercial-portable-air-conditioner-7kk21","provider":"HC Air Solutions","version":"1.0","type":"link"}