{"product_id":"triangle-engineering-36-heat-buster-belt-drive-drum-fan","title":"Triangle Engineering 36\" Heat Buster Belt-Drive Drum Fan","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eOverheating Work Areas and Stagnant Air? This 36\" Belt-Drive Drum Fan Delivers Powerful Spot Cooling That Makes Large Spaces Workable Again\u003c\/h2\u003e\n\u003cp\u003eHeat buildup is part of life in warehouses, factories, and shops—but that doesn’t mean your team has to work in stagnant air. The Heatbuster drum fan by Triangle Engineering is designed for one clear job: moving a large volume of air exactly where people and processes need it most.\u003c\/p\u003e\n\u003cp\u003eThis 36-inch drum fan delivers roughly 12,100 CFM, making it a practical solution for large, open spaces where full building air conditioning isn’t realistic. Instead of trying to cool everything, it focuses airflow on work areas—aisles, loading docks, staging zones, and production lines—where better air movement immediately improves comfort and productivity.\u003c\/p\u003e\n\u003cp\u003eThe fan creates a strong, directional airstream that helps break up hot spots and reduce air stratification. That steady airflow makes a noticeable difference, especially in non-conditioned buildings, by increasing air speed across workers. Even when temperatures stay the same, the space simply feels more tolerable. That matters during long shifts and peak summer months.\u003c\/p\u003e\n\u003cp\u003eA key advantage of this \u003ca rel=\"noopener\" title=\"drum fan\" href=\"https:\/\/hcairsolutions.com\/collections\/drum-fans\" target=\"_blank\"\u003edrum fan\u003c\/a\u003e is its belt-drive design operating at approximately 500 RPM. Running the fan wheel at a lower speed allows it to move a lot of air without the harsh noise and vibration common with smaller, high-RPM units. The result is smoother airflow, quieter operation, and equipment that holds up better over time. Keeping the motor out of the direct airstream also helps protect it from dust, fumes, and heat—an important detail in industrial environments.\u003c\/p\u003e\n\u003cp\u003eMobility is another reason this fan works so well. Built with rubber wheels it can be rolled to where airflow is needed most. Whether it’s temporary spot cooling, seasonal heat control, or supporting specific processes like drying floors or parts, the fan adapts as the workspace changes.\u003c\/p\u003e\n\u003cp\u003eIf you’ve considered a barrel fan for a warehouse or shop, this size and airflow range hits a reliable middle ground. It’s large enough to affect a meaningful area, yet still easy to reposition as work shifts throughout the day.\u003c\/p\u003e\n\u003cp\u003eThe Heatbuster isn’t about overcomplicating ventilation. It’s about dependable, high-volume air movement that improves comfort, supports operations, and fits the realities of industrial spaces. Simple, effective, and built to work where HVAC coverage falls short.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 333.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eBlade Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e36 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e21\" x 40\" x 42\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e143 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eDrive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003eBelt Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e1\/2 Hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 66.0808%;\"\u003e\u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%;\"\u003e7.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e1 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eCFM\/RPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e12,100\/500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eMotor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003eTEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003eContinuous Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e10' with Molded Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\n\u003cbr\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful 12,100 CFM Airflow\u003c\/strong\u003e\u003cbr\u003eThe 36\" blade delivers high-volume airflow to provide effective spot cooling, helping reduce heat buildup and improve comfort and productivity in large spaces.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Belt Drive System\u003c\/strong\u003e\u003cbr\u003eFeatures a rugged belt drive operating at 500 RPM for smoother operation, reduced vibration, and extended motor life compared to direct-drive alternatives.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Wide-Body Barrel Construction\u003c\/strong\u003e\u003cbr\u003eThe wide body steel barrel is designed for maximum airflow efficiency while standing up to harsh job-site conditions and continuous use.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous-Duty TEFC Motor\u003c\/strong\u003e\u003cbr\u003eEquipped with a 1\/2 HP Totally Enclosed Fan Cooled (TEFC) motor rated for continuous duty, protecting internal components from dust and debris for long-term reliability.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe, Portable \u0026amp; Easy to Use\u003c\/strong\u003e\u003cbr\u003eOSHA-compliant spiral wound safety guards, a full-width easy-grip handle, and a 10' power cord with molded plug make this fan safe, mobile, and ready to use right out of the box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003eManual\u003c\/p\u003e","brand":"Triangle Engineering","offers":[{"title":"Default Title","offer_id":42423891492953,"sku":"TPC3613-T","price":1295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/36HeatBusterBeltDriveDrumFan_TPC3613-T_pic3.png?v=1750732481","url":"https:\/\/hcairsolutions.com\/products\/triangle-engineering-36-heat-buster-belt-drive-drum-fan","provider":"HC Air Solutions","version":"1.0","type":"link"}