{"product_id":"triangle-engineering-36-heat-buster-slim-1-speed-belt-drive-drum-fan","title":"Triangle Engineering 36\" Heat Buster Slim 1 Speed Belt-Drive Drum Fan","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eTired of Hot Spots and Poor Airflow? This 36\" Belt-Drive Slim Drum Fan Pushes Massive Airflow to Keep Large Spaces Moving\u003c\/h2\u003e\n\u003cp\u003eThe HeatBuster Slim is designed for one job—moving a lot of air in places where heat and stagnant conditions slow everything down. This drum fan is built for warehouses, factories, and workshops that need consistent, high-velocity airflow across large open spaces, not the light breeze smaller fans produce.\u003c\/p\u003e\n\u003cp\u003eLarge facilities create their own heat. Equipment runs nonstop, doors open and close, and air settles where it shouldn’t. The HeatBuster Slim addresses that problem head-on with powerful circulation that pushes air across long distances while keeping a slim footprint. Its narrow profile fits neatly into tight aisles, along walls, or near work zones without getting in the way of daily operations.\u003c\/p\u003e\n\u003cp\u003eAt the core of this fan is a belt-drive system engineered for commercial and industrial use. Compared to direct-drive units, belt-drive designs reduce stress on the motor and hold up better during continuous operation. That matters in environments where fans aren’t switched off at lunch. The result is dependable airflow with less wear over time—something maintenance teams tend to appreciate.\u003c\/p\u003e\n\u003cp\u003eYou’ll often see this style of fan, sometimes referred to as a barrel fan, used for spot cooling on warehouse floors, improving airflow near loading docks, or circulating air through dusty or humid areas. It’s also effective for supporting evaporation during cleanup or drying processes, especially in buildings without full HVAC coverage.\u003c\/p\u003e\n\u003cp\u003eThe construction keeps things practical. An impact-resistant housing stands up to bumps and rough handling, while the OSHA-compliant grille adds a layer of safety in busy work environments. Built-in wheels make it easy to reposition as layouts change or workflows shift throughout the day.\u003c\/p\u003e\n\u003cp\u003eTriangle Engineering kept the design straightforward for a reason. No unnecessary adjustments. No complicated controls. Just steady, high-volume air movement where it’s needed most.\u003c\/p\u003e\n\u003cp\u003eIn short, this \u003ca href=\"https:\/\/hcairsolutions.com\/collections\/drum-fans\" title=\"drum fan\" rel=\"noopener\" target=\"_blank\"\u003edrum fan\u003c\/a\u003e is built for facilities that need real airflow without sacrificing durability or space. If your operation depends on keeping air moving reliably, the HeatBuster Slim fits right in.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable style=\"width: 100%; height: 282.344px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eBlade Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e36 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e21\" x 40\" x 40\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e113 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDrive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eBelt Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 66.0808%;\"\u003e\u003cstrong\u003eNumber of Speeds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e1\/2 Hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e7.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e1 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eCFM\/RPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e12,100\/500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eMotor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eODP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eContinuous Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 24px;\"\u003e\u003cstrong\u003ePower Cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 24px;\"\u003e10' with Molded Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\n\u003cbr\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Volume Commercial \u0026amp; Industrial Airflow (12,000+ CFM)\u003c\/strong\u003e\u003cbr\u003eDesigned to move large volumes of air—typically over 12,000 CFM—this fan effectively reduces heat buildup and improves air circulation in warehouses, factories, and large open facilities.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Belt-Drive System\u003c\/strong\u003e\u003cbr\u003eThe belt-drive configuration reduces motor stress compared to direct-drive fans, supporting quieter operation and longer service life during continuous, high-demand use.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Motor Performance\u003c\/strong\u003e\u003cbr\u003ePowered by a durable, continuous-duty motor engineered for industrial airflow demands, delivering reliable circulation for cooling, ventilation, and moisture control.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Belt Tensioning\u003c\/strong\u003e\u003cbr\u003eAn integrated automatic belt tensioner maintains proper belt alignment, minimizing routine adjustments and helping ensure consistent performance over time.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim Drum Profile for Space-Restricted Areas\u003c\/strong\u003e\u003cbr\u003eThe narrow barrel design allows placement in tight aisles, along walls, or near equipment without obstructing workflows, making it ideal for crowded industrial environments.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Steel Barrel Construction\u003c\/strong\u003e\u003cbr\u003eBuilt with heavy-gauge steel, the fan housing resists dents and wear, standing up to daily use in demanding industrial and commercial settings.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOSHA-Compliant Safety Guard\u003c\/strong\u003e\u003cbr\u003eThe spiral-wound wire grille meets OSHA safety requirements, protecting personnel while allowing unrestricted airflow across the fan’s full diameter.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable Design for Flexible Placement\u003c\/strong\u003e\u003cbr\u003eDespite its heavy-duty construction, the slim drum format allows for easier repositioning as facility layouts or airflow needs change.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003eManual\u003c\/p\u003e","brand":"Triangle Engineering","offers":[{"title":"Default Title","offer_id":42454785392729,"sku":"SPL3613","price":1251.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/36HeatBusterSlimBeltDriveDrumFan.jpg?v=1750656040","url":"https:\/\/hcairsolutions.com\/products\/triangle-engineering-36-heat-buster-slim-1-speed-belt-drive-drum-fan","provider":"HC Air Solutions","version":"1.0","type":"link"}