{"product_id":"triangle-engineering-42-heat-buster-belt-drive-drum-fan","title":"Triangle Engineering 42\" Heat Buster Belt-Drive Drum Fan","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eToo Hot to Work Efficiently? This 42\" Belt-Drive Drum Fan Blasts Air Across Large Areas to Cool People, Equipment and Processes\u003c\/h2\u003e\n\u003cp\u003eWhen it comes to moving air across big, open spaces, size and power matter. The Heatbuster drum fan from Triangle Engineering delivers both. With a 42‑inch diameter, belt‑drive design, 16,990 CFM airflow, and 475 RPM, this fan moves massive volumes of air quietly and efficiently—enough to cool people, equipment, and entire work areas without the noise or turbulence of smaller, high-speed fans.\u003c\/p\u003e\n\u003cp\u003eLarge warehouses, factories, and workshops often have hot spots—think assembly lines, dock doors, or machines pumping out heat all day. This drum fan tackles them head-on, providing targeted airflow exactly where it’s needed. And because it’s portable, you can easily move it between aisles, workstations, or temporary setups. It’s flexibility and power rolled into one heavy-duty package.\u003c\/p\u003e\n\u003cp\u003eComfort isn’t the only concern. Heat can shorten equipment life, slow productivity, and even create safety hazards. The Heatbuster drum fan keeps air moving across machinery and electronics, helping reduce overheating and extending service life. It also improves overall air circulation, cutting down on stagnant, stuffy areas and making conditioned air more effective in partially cooled spaces.\u003c\/p\u003e\n\u003cp\u003eNeed quick drying or moisture control? High-volume airflow speeds up floor drying, reduces damp spots near dock doors, and helps manage humidity in storage zones. And while it’s no replacement for proper exhaust systems, this drum fan can also help dilute fumes, odors, and dust—making the workspace healthier and more comfortable.\u003c\/p\u003e\n\u003cp\u003eWhat sets this fan apart is its belt-drive design. By running the motor faster than the blades, it keeps airflow strong while minimizing noise and vibration—a big win for any environment where people are working nearby all day. It’s a practical, long-lasting solution for workplaces that demand performance without constant distraction.\u003c\/p\u003e\n\u003cp\u003eIn short, the Heatbuster is more than just a fan—it’s an industrial-grade \u003ca rel=\"noopener\" title=\"drum fan\" href=\"https:\/\/hcairsolutions.com\/collections\/drum-fans\" target=\"_blank\"\u003edrum fan\u003c\/a\u003e engineered for real-world challenges. From cooling employees and equipment to improving air circulation and comfort, it’s the kind of fan that makes a noticeable difference the moment you turn it on. If your space is large, hot, or poorly ventilated, this is exactly what you need.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable style=\"width: 100%; height: 262.75px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eBlade Diameter \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e42 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e21\" x 45\" x 47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e193 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDrive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eBelt Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e1 Hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 66.0808%;\"\u003e\u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%;\"\u003e11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e1 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eCFM\/RPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e16,990\/475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eMotor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eTEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eContinuous Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 24px;\"\u003e\u003cstrong\u003ePower Cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 24px;\"\u003e10' with Molded Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\n\u003cbr\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli data-end=\"566\" data-start=\"383\"\u003e\n\u003cp data-end=\"566\" data-start=\"385\"\u003e\u003cstrong data-end=\"430\" data-start=\"385\"\u003eMassive 42\" Blade for High-Volume Airflow\u003cbr\u003e\u003c\/strong\u003eMoves up to 16,990 CFM, delivering powerful, wide-reaching airflow to cool large open spaces, hot spots, and machinery efficiently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"772\" data-start=\"568\"\u003e\n\u003cp data-end=\"772\" data-start=\"570\"\u003e\u003cstrong data-end=\"598\" data-start=\"570\"\u003eRugged Belt-Drive Design\u003cbr\u003e\u003c\/strong\u003eRuns the motor at higher speed while spinning the fan blades slower, providing quieter operation, reduced vibration, and longer motor life compared to direct-drive fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"984\" data-start=\"774\"\u003e\n\u003cp data-end=\"984\" data-start=\"776\"\u003e\u003cstrong data-end=\"814\" data-start=\"776\"\u003eContinuous Duty Motor\u003cbr\u003e\u003c\/strong\u003eEquipped with a 1 HP, TEFC (Totally Enclosed Fan-Cooled) motor designed for continuous operation, ensuring reliable performance in demanding industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1206\" data-start=\"986\"\u003e\n\u003cp data-end=\"1206\" data-start=\"988\"\u003e\u003cstrong data-end=\"1019\" data-start=\"988\"\u003ePortable and Easy to Handle\u003cbr\u003e\u003c\/strong\u003eWide-body barrel with full-width grip handle and durable wheels allows easy movement between aisles, workstations, or temporary setups, giving flexibility wherever cooling is needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1383\" data-start=\"1208\"\u003e\n\u003cp data-end=\"1383\" data-start=\"1210\"\u003e\u003cstrong data-end=\"1244\" data-start=\"1210\"\u003eOSHA-Compliant Safety Features\u003cbr\u003e\u003c\/strong\u003eSpiral-wound fan guards provide maximum safety without sacrificing airflow, protecting workers and equipment from contact with blades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1570\" data-start=\"1385\"\u003e\n\u003cp data-end=\"1570\" data-start=\"1387\"\u003e\u003cstrong data-end=\"1413\" data-start=\"1387\"\u003eConvenient Power Setup\u003cbr\u003e\u003c\/strong\u003e115V, single-phase motor with 10' power cord and molded plug ensures quick setup and compatibility in standard warehouse, shop, or factory environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003eManual\u003c\/p\u003e","brand":"Triangle Engineering","offers":[{"title":"Default Title","offer_id":42423895326809,"sku":"TPC4215","price":1595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/42HeatBusterBeltDriveDrumFan_TPC4213-T_pic3.png?v=1750732460","url":"https:\/\/hcairsolutions.com\/products\/triangle-engineering-42-heat-buster-belt-drive-drum-fan","provider":"HC Air Solutions","version":"1.0","type":"link"}