{"product_id":"triangle-engineering-42-portable-cooler-hd-1-speed-direct-drive-drum-fan","title":"Triangle Engineering 42\" Portable Cooler HD 1 Speed Direct-Drive Drum Fan","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eAre You Struggling With Heat and Stagnant Air? This 42\" Direct-Drive Drum Fan Moves High-Volume Air to Cool Large Work Areas Fast\u003c\/h2\u003e\n\u003cp\u003eHeat rarely spreads evenly in warehouses and industrial spaces. It builds up around dock doors, production lines, and equipment, while hot air settles overhead. Smaller floor fans can help locally, but they often can’t move air far enough to matter in large, open areas. That’s where a full-size \u003ca rel=\"noopener\" title=\"drum fan\" href=\"https:\/\/hcairsolutions.com\/collections\/drum-fans\" target=\"_blank\"\u003edrum fan\u003c\/a\u003e comes in.\u003c\/p\u003e\n\u003cp\u003eThe cooler HD fan from Triangle Engineering is a 42 inch portable, direct drive unit built to move a high volume of air across wide spaces. With airflow capacity in the tens of thousands of CFM (13,000+), it pushes air down long aisles and across open bays, helping reduce hot spots and improve overall air circulation in high-ceiling facilities.\u003c\/p\u003e\n\u003cp\u003eIn non-conditioned or partially conditioned spaces, increased air movement improves comfort by enhancing evaporative cooling on the body. Workers feel cooler, and equipment benefits from reduced heat buildup around chargers, compressors, and staging zones. Increased air movement is also recognized by OSHA as a practical way to help manage indoor heat stress.\u003c\/p\u003e\n\u003cp\u003eThis fan also supports general ventilation. When aimed toward open dock doors or exhaust points, it helps sweep out stagnant air, fumes, and odors commonly found in shipping, loading, and production areas. In workshops and repair bays, that same airflow helps dilute welding fumes, solvent vapors, and airborne dust.\u003c\/p\u003e\n\u003cp\u003eThe direct drive motor eliminates belts and pulleys, reducing maintenance and improving reliability during long operating hours. Fewer moving parts mean consistent performance and less downtime in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eBuilt on heavy-duty wheels, the fan can be moved quickly between work areas as needs change throughout the day. One unit can often replace multiple smaller fans, simplifying power requirements and floor layout. It fits naturally alongside other industrial warehouse fans and complements larger portable ventilation solutions. Often called a barrel fan, this design is chosen when strong, directional airflow and durability are the priority.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable style=\"width: 100%; height: 321.531px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eBlade Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e42 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e21\" x 45\" x 46\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e121 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eDrive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003eDirect Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e1\/2 Hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Speeds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 19.5938px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 19.5938px;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e1 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eCFM (High-Low)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e13,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 19.5938px;\"\u003e\u003cstrong\u003eRPM (High-Low)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 19.5938px;\"\u003e825\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eMotor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003eTEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 23.875px;\"\u003eContinuous Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px;\"\u003e\n\u003ctd style=\"width: 49.8195%; height: 24px;\"\u003e\u003cstrong\u003ePower Cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.8195%; height: 24px;\"\u003e10' with Molded Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\n\u003cbr\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli data-end=\"609\" data-start=\"335\"\u003e\n\u003cp data-end=\"609\" data-start=\"337\"\u003e\u003cstrong data-end=\"383\" data-start=\"337\"\u003e42\" High-Velocity Airflow for Large Spaces (13,600 CFM)\u003c\/strong\u003e\u003cbr data-end=\"386\" data-start=\"383\"\u003eThe 42-inch blade diameter delivers powerful, wide-area airflow designed for warehouses, factories, and workshops where smaller fans can’t reach far enough. Ideal for long aisles, open bays, and high-ceiling environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"853\" data-start=\"611\"\u003e\n\u003cp data-end=\"853\" data-start=\"613\"\u003e\u003cstrong data-end=\"663\" data-start=\"613\"\u003eDirect-Drive Motor Eliminates Belt Maintenance\u003c\/strong\u003e\u003cbr data-end=\"666\" data-start=\"663\"\u003eA ½ HP direct-drive motor removes belts and pulleys from the equation, reducing maintenance, downtime, and performance loss over time—especially important for continuous industrial use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1082\" data-start=\"855\"\u003e\n\u003cp data-end=\"1082\" data-start=\"857\"\u003e\u003cstrong data-end=\"901\" data-start=\"857\"\u003eMoves Heat, Fumes, and Stagnant Air Fast\u003c\/strong\u003e\u003cbr data-end=\"904\" data-start=\"901\"\u003eHigh CFM output helps break up hot spots, sweep stagnant air toward open doors or exhaust points, and dilute fumes or odors in loading docks, production areas, and repair bays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1319\" data-start=\"1084\"\u003e\n\u003cp data-end=\"1319\" data-start=\"1086\"\u003e\u003cstrong data-end=\"1140\" data-start=\"1086\"\u003eImproves Worker Comfort and Heat Stress Conditions\u003c\/strong\u003e\u003cbr data-end=\"1143\" data-start=\"1140\"\u003eIncreased air velocity enhances evaporative cooling on the body, helping workers feel cooler in non-conditioned or partially conditioned spaces where HVAC alone isn’t enough.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1540\" data-start=\"1321\"\u003e\n\u003cp data-end=\"1540\" data-start=\"1323\"\u003e\u003cstrong data-end=\"1378\" data-start=\"1323\"\u003eRugged Steel Drum Built for Industrial Environments\u003c\/strong\u003e\u003cbr data-end=\"1381\" data-start=\"1378\"\u003eThe painted steel housing is designed to withstand daily use around forklifts, pallet jacks, and busy shop floors without compromising performance or safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1751\" data-start=\"1542\"\u003e\n\u003cp data-end=\"1751\" data-start=\"1544\"\u003e\u003cstrong data-end=\"1584\" data-start=\"1544\"\u003eTEFC Motor Rated for Continuous Duty\u003c\/strong\u003e\u003cbr data-end=\"1587\" data-start=\"1584\"\u003eThe Totally Enclosed Fan Cooled (TEFC) motor is suited for dusty, industrial conditions and long run times, providing dependable operation across multiple shifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1973\" data-start=\"1753\"\u003e\n\u003cp data-end=\"1973\" data-start=\"1755\"\u003e\u003cstrong data-end=\"1799\" data-start=\"1755\"\u003ePortable Design with Heavy-Duty Mobility\u003c\/strong\u003e\u003cbr data-end=\"1802\" data-start=\"1799\"\u003eBuilt-in wheels and a balanced frame allow quick repositioning between work zones, dock doors, and staging areas—one fan can serve multiple locations throughout the day.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2154\" data-start=\"1975\"\u003e\n\u003cp data-end=\"2154\" data-start=\"1977\"\u003e\u003cstrong data-end=\"2016\" data-start=\"1977\"\u003eSimple 115V Plug-and-Play Operation\u003c\/strong\u003e\u003cbr data-end=\"2019\" data-start=\"2016\"\u003eRuns on standard 115V single-phase power with a 10-foot cord, making it easy to deploy without special wiring or electrical upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003eManual\u003c\/p\u003e","brand":"Triangle Engineering","offers":[{"title":"Default Title","offer_id":42976581058649,"sku":"PC4213","price":1151.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/42PortableCoolerHD2SpeedDrumFan.webp?v=1768035716","url":"https:\/\/hcairsolutions.com\/products\/triangle-engineering-42-portable-cooler-hd-1-speed-direct-drive-drum-fan","provider":"HC Air Solutions","version":"1.0","type":"link"}