{"product_id":"triangle-engineering-60-heat-buster-belt-drive-drum-fan","title":"Triangle Engineering 60\" Heat Buster Belt-Drive Drum Fan","description":"\u003ch6\u003eOVERVIEW\u003c\/h6\u003e\n\u003ch2\u003eCan’t Get Enough Air Movement? This 60\" Belt-Drive Drum Fan Circulates 30,000+ CFM to Improve Comfort Across Big Zones\u003c\/h2\u003e\n\u003cp\u003eWhen large spaces heat up, small fixes don’t help much. That’s where a true drum fan earns its keep. The Triangle Engineering Heatbuster is designed for warehouses, factories, and workshops that need powerful, reliable air movement where HVAC alone can’t keep up. This is a full-size, industrial barrel fan built to move air across wide floor areas, long aisles, and high-ceiling spaces without fuss or compromise.\u003c\/p\u003e\n\u003cp\u003eWith a 60-inch diameter and roughly 30,100 CFM of airflow, this fan doesn’t just circulate air — it pushes it with purpose. You get a long, directional throw that reaches across loading docks, production zones, and staging areas, helping reduce heat buildup and improve perceived cooling through air movement. In plain terms, it helps people feel cooler, faster, even in spaces that aren’t fully air-conditioned.\u003c\/p\u003e\n\u003cp\u003eThe belt-drive design plays a big role here. Running at about 370 RPM, the fan moves massive volumes of air without the harsh noise or vibration you’d expect from smaller, high-speed units. The motor drives the fan wheel more gently, which means quieter operation, less mechanical stress, and better suitability for long shifts or continuous use. On a busy warehouse floor where communication matters, that lower noise profile makes a real difference.\u003c\/p\u003e\n\u003cp\u003eThis size drum fan also simplifies logistics. One 60-inch unit can often replace several smaller floor or pedestal fans, reducing clutter, power requirements, and maintenance headaches. Instead of managing multiple cords and placements, you get broad, consistent airflow from a single piece of equipment.\u003c\/p\u003e\n\u003cp\u003eBeyond comfort, high-volume airflow supports better ventilation and air quality. This fan helps mix stratified air under tall ceilings, dilute fumes from forklifts or packaging materials, and speed up drying after cleaning or minor water intrusion. It’s a practical tool for heat-stress mitigation, seasonal cooling, and general airflow management in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eDespite its size, the Heatbuster stays flexible. Heavy-duty casters and a solid handle make it easy to reposition as work zones change — whether that’s shifting pick lines, temporary projects, or seasonal hot spots.\u003c\/p\u003e\n\u003cp\u003eIf you’re looking for a \u003ca href=\"https:\/\/hcairsolutions.com\/collections\/drum-fans\" title=\"drum fan\" rel=\"noopener\" target=\"_blank\"\u003edrum fan\u003c\/a\u003e or barrel fan that delivers serious airflow without unnecessary complexity, this one fits the bill. It’s straightforward, durable, and designed to handle the kind of spaces where air movement isn’t optional — it’s essential.\u003c\/p\u003e\n\u003ch6\u003eSPECIFICATIONS\u003c\/h6\u003e\n\u003ctable style=\"width: 100%; height: 282.344px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eBlade Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e60 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e25\" x 63\" x 68\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e242 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDrive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eBelt Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eHorsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e1.5 Hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 19.5938px;\"\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e1 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eCFM\/RPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003e30,100\/370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eMotor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eODP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 23.875px;\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 23.875px;\"\u003eContinuous Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px;\"\u003e\n\u003ctd style=\"width: 66.0808%; height: 24px;\"\u003e\u003cstrong\u003ePower Cord\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.7434%; height: 24px;\"\u003e20' with Molded Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch6\u003e\n\u003cbr\u003eFEATURES\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Volume Airflow for Spot Cooling and Ventilation\u003c\/strong\u003e\u003cbr\u003eWith up to 30,100 CFM, this drum fan delivers strong bulk airflow to help reduce heat buildup, improve perceived cooling, and assist with ventilation in spaces where HVAC coverage is limited or uneven.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty 60\" Wide-Body Barrel Design\u003c\/strong\u003e\u003cbr\u003eThe oversized barrel and 60-inch blade are built for serious air movement across large, open areas. This wide body helps deliver a steady, directional airflow that reaches farther than smaller floor or pedestal fans, making it ideal for warehouses, docks, and production floors.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful 1.5 HP Motor with 115V Single-Phase Power\u003c\/strong\u003e\u003cbr\u003eThe 1.5 horsepower motor provides the muscle needed for large airflow while operating on standard 115V, single-phase power, keeping installation simple without special electrical requirements.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBelt-Drive Construction for Quieter, Longer-Lasting Operation\u003c\/strong\u003e\u003cbr\u003eThe belt-drive system allows the fan blade to turn at a lower 370 RPM while the motor runs efficiently. This reduces noise, vibration, and wear, making the fan better suited for long shifts and continuous seasonal use.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineered for Continuous-Duty Industrial Use\u003c\/strong\u003e\u003cbr\u003eDesigned to run all day, every day, the HeatBuster is rated for continuous duty, making it dependable during peak summer heat, extended shifts, or ongoing ventilation needs without frequent shutdowns.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOSHA-Compliant Spiral Wound Safety Guards\u003c\/strong\u003e\u003cbr\u003eHeavy-duty spiral wound guards meet OSHA requirements, helping protect workers, tools, and equipment around the fan — an important consideration on busy shop floors and loading areas.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable Design with Full-Width Easy-Grip Handle\u003c\/strong\u003e\u003cbr\u003eA rugged frame paired with a full-width handle makes repositioning straightforward. This fan can be moved where airflow is needed most, whether that’s shifting work zones, seasonal hot spots, or temporary projects.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for Real-World Job Sites\u003c\/strong\u003e\u003cbr\u003eFrom the ODP motor enclosure to the 20-foot power cord with molded plug, every detail is designed for practical industrial use — reliable performance, easy servicing, and fewer headaches over the long run.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003ePRODUCT SHEETS\u003c\/h6\u003e\n\u003cp\u003edef\u003c\/p\u003e","brand":"Triangle Engineering","offers":[{"title":"Default Title","offer_id":42423905452121,"sku":"TPC6016","price":3795.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/4031\/5737\/files\/60HeatBusterBeltDriveDrumFan_TPC6016_picture3.png?v=1750732448","url":"https:\/\/hcairsolutions.com\/products\/triangle-engineering-60-heat-buster-belt-drive-drum-fan","provider":"HC Air Solutions","version":"1.0","type":"link"}